Download e-book for iPad: Detection of Nuclear and Radiological Weapons by Philips Gary W., Nagel David J., Coffey Timothy

By Philips Gary W., Nagel David J., Coffey Timothy

Show description

Read or Download Detection of Nuclear and Radiological Weapons PDF

Best military equipment: weapon books

Download e-book for kindle: F-111 Aardvark by B.Kinzey

Книга F-111 Aardvark F-111 Aardvark Книги Вооружение Автор: B. Kinzey Формат: pdf Страниц: seventy six Размер: 35. sixty nine Язык: Английский0 (голосов: zero) Оценка:in aspect & scale №4

Download e-book for kindle: Republic P-47 Thunderbolt Vol.4 by T Szlagor, L a Wieliczko

Книга Kagero Monographs No. 28 - Republic P-47 Thunderbolt Vol. four Kagero Monographs No. 28 - Republic P-47 Thunderbolt Vol. four Книги Вооружение Автор: Tomasz Szlagor Год издания: 2006 Формат: pdf Издат. :Kagero Oficyna Wydawnicza Страниц: one hundred and one Размер: 37. 24 ISBN: 8360445133 Язык: Английский0 (голосов: zero) Оценка:Язык: польский/английский (Polish/English)Fulfilling the jobs of an escort fighter, a fighter-bomber (in which it excelled), or even an air-sea rescue carrier airplane, P-47 used to be current on essentially all very important fronts of the WWII.

Get Warfare at Sea, 1500-1650: Maritime Conflicts and the PDF

The writer of the awesome two-volume paintings "Navies and Nations", Swedish Naval historian Jan Glete, provides us a great comparative learn of conflict at Sea and its implications for early ecu states during this obtainable, but sturdy examine. As a naval officer and PhD scholar in comparative politics, there are particularly useful positive aspects of the booklet that i want to emphasize.

Extra resources for Detection of Nuclear and Radiological Weapons

Example text

NaI detectors have a limited energy resolution of about 8% for the 662 keV gamma rays from 137Cs. Solid-state semiconductor detectors convert the gamma-ray energy directly to an electronic pulse that is then recorded by a PHA. 2%, or forty times better than NaI, and produce a high-resolution spectrum with sharp peaks rising above an underlying continuum. This superior resolution allows precise determination of the gamma-ray energy, separation of close-lying peaks, and identification of weak peaks in the presence of a strong interfering background.

Cadmium telluride (CdTe), cadmium zinc telluride (CZT) and mercuric iodide (HgI) semiconductor diode detectors are currently available commercially (table 12). For CZT, best efforts to date have produced detectors with about Figure 16. Calibration curves of peak detection efficiency versus gamma-ray energy for 32% relative efficiency coaxial Ge detectors [ORTEC, 2004]. The curve labeled GEM is for a standard p-type detector and GMX for an n-type detector with a thin Be window. 13 keV (2%) resolution at 662 keV.

5x2, 2x2, 3x3” Note a. berkeleynucleonics. 5, 2x2, 3x3” Note a. Other sizes available on request 1x1, 2x2, 3x3” Note a. Interfaces with portable analyzer. 5x2, 2x2, 3x3” Semirugged weather resistant assembly 3 x 14” overall/ 3 kg/ +12V at 20mA/$731 (2x2), $937 (3x3) Note a. 5 to 5” diameter Available with integrated photomultiplier and high voltage power supply Note a. 8 lb). 8 in. Typical weight: about 8 lb. Typical resolution: 7% at 662 keV, 5% at 1332 keV, typical cost < $1,000 including PM tube and base.

Download PDF sample

Detection of Nuclear and Radiological Weapons by Philips Gary W., Nagel David J., Coffey Timothy


by Mark
4.1

Rated 4.13 of 5 – based on 35 votes